Exceptional Breathability (Up to 31%+): The micro-porous non-woven rayon and perforated backing structures allow air and moisture vapor to pass freely, eliminating dampness under the tape to prevent skin maceration, minimize bacterial growth, and accelerate healing.
Hypoallergenic & Biocompatible Safety: Utilizing premium medical-grade acrylic pressure-sensitive adhesive that is entirely free of natural rubber latex or volatile solvent rubbers. The entire series is ISO 10993 certified and fully compliant with biological compatibility safety assessments, ensuring gentle security for ultra-fragile skin, pediatric, and geriatric patients.
Moisture-Stable & Versatile Adhesion: The acrylic adhesive maintains a reliable tack on damp or moist skin surfaces, resists detachment under physical movement, and operates stably across a wide temperature range of -20°C to 80°C.
Flexible, Light, and Conformable: The ultra-thin, low-profile material naturally flexes and contours to organic anatomical curves and joint creases without curling or lifting at the edges, ensuring unrestricted patient mobility.
Convenient Bidirectional Hand-Tearing: Designed for rapid clinical operation; the 1527 series supports clean, straight hand-tearing both horizontally and vertically, while the 1530 and 1533 styles offer quick hand-tearing without the need for scissors or cutting dispensers, reducing clinical waste.
Clinical Monitoring Convenience: The 1527 variant features a highly transparent plastic backing, enabling medical professionals to easily inspect skin conditions, wound progress, or catheter insertion sites without removing the tape.
Advanced Die-Cutting Integration (1530L / 1533L): Models ending in "L" come pre-laminated with high-strength, silicon-coated protective release liners (such as 63# paper), bypassing the need for secondary web laminations and optimizing high-speed automated flatbed or rotary die-cutting processes.
Sterilization & Cleanroom Readiness: Fully compatible with Ethylene Oxide (EtO) and Gamma Ray sterilization protocols, allowing seamless integration into finished sterile medical device production and cleanroom-compliant packaging lines.
Precision Custom Fabrication: Delivered with 100% genuine 3M product traceability from an authorized converter, available at an ultra-low MOQ of 1 PC. MACTAPE delivers custom X-Y axis die-cut dimensions, specific widths, sheets, or rolls with tight tolerances within $\pm0.2\text{mm}$ and perfectly clean, burr-free edges.
Model | Tape Base Material Type | Tape Color / Finish | Release Liner Configuration | Dimensions / Standard Pack Options | Primary Application Field |
1527C-0 | Perforated PET/EVA Film | Transparent | None (Self-Wound) | 1.2 cm × 9.1 m; 24 rolls/box, 10 boxes/case | Strong tubing, heavy catheter anchoring, waterproof surface needs. |
1527C-1 | Perforated PET/EVA Film | Transparent | None (Self-Wound) | 2.4 cm × 9.1 m; 12 rolls/box, 10 boxes/case | Strong tubing, heavy catheter anchoring, waterproof surface needs. |
1527C-S | Perforated PET/EVA Film | Transparent | None (Self-Wound) | 1.0 cm × 9.1 m | Narrow-width precision medical electronics, clinical skin securing. |
1527-3 | Perforated Plastic Base | Transparent | None (Self-Wound) | 7.5 cm × 9.1 m; 4 rolls/box, 10 boxes/case | Wide-area dressing fixation, secondary clinical device securing. |
1527MS | Embossed Perforated EVA | Transparent | None (Single-Coated) | Custom Widths / Roll Stock | Medical equipment fabrication, custom advanced dressing manufacturing. |
1533-0 | Non-woven Rayon backing | Tan / Skin Tone | None (Self-Wound) | 1.25 cm × 9.1 m; 24 rolls/box, 10 boxes/case | Concealed dressing securing, gentle skin attachment, IV needles. |
1533L | Non-woven Rayon backing | Tan / Skin Tone | 63# Silicone Release Paper | Master roll width up to 1220 mm; Thickness: 0.14 mm (Customizable) | Industrial automated converting, die-cut healthcare device components. |
1530C-0 | Non-woven Rayon backing | White | None (Self-Wound) | 1.2 cm × 9.1 m; 24 rolls/box, 10 boxes/case | Fragile skin care, lightweight dressing retention, IV line tracking. |
1530C-1 | Non-woven Rayon backing | White | None (Self-Wound) | 2.4 cm × 9.1 m; 12 rolls/box, 10 boxes/case | Fragile skin care, lightweight dressing retention, IV line tracking. |
1530C-2 | Non-woven Rayon backing | White | None (Self-Wound) | 4.8 cm × 9.1 m; 6 rolls/box, 10 boxes/case | Medium dressing fixation, general clinical device stabilization. |
1530C-3 | Non-woven Rayon backing | White | None (Self-Wound) | 7.2 cm × 9.1 m; 4 rolls/box, 10 boxes/case | Wide-area wound pad backing, orthopedic dressing stabilization. |
1530L | Non-woven Rayon backing | White | Poly-coated Silicone Release Paper | Master roll width up to 1220 mm; Thickness: 0.14 mm (Customizable) | High-speed automated manufacturing, electrode pads, wound |
Skin / Surface Preparation: Apply the tape exclusively to intact, clean, thoroughly dry skin that is free of sweat, oils, chemical solvents, or topical creams. Do not apply adhesive tape directly onto open, uncovered wounds.
Lamination & Pressing: Place the tape smoothly over the target area. Press firmly outward from the center toward both edges to guarantee uniform contact and eliminate air bubbles. For reliable clinical anchorage, ensure a bonding width of at least 2–3 cm on the skin.
Environmental Considerations: Optimal initial bond strength is achieved at normal, comfortable room temperatures. Avoid applying the tape in extreme humidity, sub-zero temperatures, or airborne dust-heavy zones, as severe climate fluctuations can degrade initial tack.
Curing & Stabilization: For extended wear-time applications, allow up to 24 hours for the pressure-sensitive adhesive to reach peak holding capacity. Avoid vigorous physical rubbing, mechanical shear stress, or prolonged water exposure during the initial application phase.
Substrate & Scenario Matching:
Select the 1527 series for high-strength requirements such as securing heavy medical tubing, drainage lines, and infusion catheters. The waterproof surface keeps the bond secure during liquid contact.
Select the 1530 and 1533 series for gentle skin tracking, securing light dressings, or anchoring IV needles over fragile, sensitive areas.
While inherently hypoallergenic and engineered for all age groups, it is recommended to perform a localized patch test on a small area of skin before starting mass clinical application on highly sensitive individuals.